Fluoroscopic Imaging Equipment

Fluoroscopic Imaging Equipment

Fluoroscopic Imaging Equipment

Fluoroscopy is a type of medical imaging that shows a continuous X-ray image on a monitor, much like an X-ray movie. During a fluoroscopy procedure, an X-ray beam is passed through the body. The image is transmitted to a monitor so the movement of a body part or of an instrument or contrast agent (“X-ray dye”) through the body can be seen in detail.

C-Arms

kmc-950

Spinel 3G
[Optional 12″ Image Intensifier]

KMC-950 SYSTEM SPECIFICATIONS

KMC-950 Specification Information

Digital Imaging Management System

H.F. Generator & Rotating Anode Tube with Digital Workstation

High Frequency Generator

  • 125kV/100 mA for Rad
  • 125kV/20 mA for Boost Fluoro

Microprocessor Control & APR Panel

LCD Touch Control Screen & Window

High Power Inverter:  12.5 kW

High Resolution II Tube:  9” II (Triple Mode)

X-Ray Tube:  Rotating Anode Tube

Focal Size:  0.3 – 0.6 mm micro filament

High resolution & contrast in image quality

Pulsed fluoro for dose reduction

Boost fluoro (20mA) for high contrast image

Auto Brightness Control (ABC) for fluoro image

Motorized & Rotating Collimator

CCD Camera     1K x 1K

19” LCD Flat Panel Monitor.  LIH and noise reduction

Digital Image Management System (CX-Viewer Software)

DICOM network (Send and Work List)

Power Requirement:  110/220 VCA, 50/60 Hz

45 degree over scan

32” Free space

CX-Viewer Digital Image Management Software & Processor

X-Ray Generator

Type:            High Frequency Inverter

Controller:        Microprocessor & PROM

OP Console:    LCD Touch Panel Screen and membrane switch

Mode: Radiographic mode (Rad)
Fluoroscopic mode (FL)

Display Panel:    LCD Window & Screen

Power Rating:    12.5 kW Inverter

KV Range:        40-125kVp, 1.0 kV increment

Rad. mA Range:    20-100mA (programmable)

Rad. mAs Range:    0.2 to 500  mAs

Fluoro mA:

Normal FL: 0.3 – 5.0 mA
Multi-pulse:  0.3-5.0 mA
Snap FL:  8.0mA (8FPS)
Boost FL:   20 mA

Exp. Timer:

Rad. Mode:  3.0 ms to 8.0 sec
FL Mode:  0 to 5.0 minutes

Auto KV:        Automatic Brightness Control (ABC) on Fluoro mode of operation

X-Ray Tube

Type:            Rotating Anode (Rad-99, Varian)

Focal Size:        0.3 mm to 0.6 mm/micro focal

Anode Target:    10 degree Target Angle/TM

Heat Capacity:    300,000 HU

kV Capacity:    125 kVp

Filtration:        0.5 mm Al. @ 100 kV

Motorized Collimator

Type: IRIS (circular) motor driven
Rotating:  360 degrees

Shutter:        One (1) pair lead blades

Diaphragms:    Two (2) sets of circular aperture

Filter:        2.5 mm AL. @ 100 kVp

Cassette Holder

Mount Type:    Mounting bracket on II Tube

Size:            24cm x 24cm  or 24cm x 30cm

Grid:            80 lines, 8:1 ratio,  28” – 32” focus

CCD Digital Camera

CCD Size:        1K x 1K

Video Signal:    1024 Lines/59.9 Hz (EIA)
Scan:  2:1 progressive

Aspect Ratio:    4:3  (H : V) ratio

Signal Output:    1:0 Vp-p  / 75 Ohm

Memory Capacity:        16 frame image memory (basic)
64 frame image memory (option)

Noise Reduction:        Up to 16 level selections

LIH:            Last Image Hold function

Image Rotation:        360 degrees continuously

Monitor

Super VGA:    19” LCD Flat Panel

Sync Master:    727 MB

Dot Pitch:        0.20 mm (H)

Matrix Size:    1600 x 1200 @ 76 Hz, flicker free

Brightness:        680 cd/m sq. or 200 fl

Color Control:    Auto. Natural color

Best Software For Image and Patient File Management

CX-Viewer Imaging Software

CX-Viewer is the advanced image management system which is designed to meet the demands of today’s complex & diversified medical Imaging acquisition and procedure for C-Arm mobile application.

“Search and View” functions make possible to quickly find a study and view all the patient’s images from database and transfer to remote location thru any PACS system.

Features

Database Management

  • Very convenient for the image storage and search
  • Easy management for patient database
  • Compare a live image and image on database side by side during a patient examination

Image Storage & Memory

  • Hard drive capacity:  160 GB Memory
  • Store more than 10,000 frames of images

Variety of Diagnostic Image Control Tools

  • Zoom, Contrast, Reverse, Rotation
  • Noise filtering, Edge Enhancement
  • Image processing: Real time and Post processing

PACS Connectivity with DICOM

  • CD Burning with viewer (DICOM)

Specifications

Computer PC System

  • Pentium IV processor &Windows XP
  • Dual CPU
  • 3 GHZ, 1.98 GB of RAM
  • 512 MB  RAM
  • 160 GB hard driver
  • Frame Grabber Board
  • Desktop case, Keyboard & Mouse
  • CX-Viewer software for Digital Image Management
  • Two-Color Monitor

Data Acquisition

  • Image Size:  1024 x 1024 (Standard NTSC)
  • Pixel Depth:  12 bits
  • Automatic Image Capture
  • Dual monitor display & operation

Image Processing

  • Window Level (contrast adjustment)
  • Real time & Post-Processing
  • Pan & Zoom Control
  • Image flip (Horizontal & Vertical)
  • Image rotation (360 degrees)
  • Noise reduction & recursive filter
  • Edge Enhancement (sharpness)

Image Management

  • Create a patient file & database
  • DICOM 3 interface with daily worklist
  • Networking to PACS (DICOM send)
  • Local Printer Connection

Overlay Image Data & Display

  • Patient, Study & Image Information
  • Annotation, text  and measurement
  • Symbol annotation:  Circle, arrow, square …etc.
  • Multiple display:  up to 5 x 5 matrix format

Image Storage

  • More than 8,000 images on 80 GB/HD
  • JPEG compression
  • Convertible to general format: BMP, PCX, GIG….etc.

Compact Size, Lightweight and Easy Maneuverability

Mechanical Specification

Unit:  mm

Weight: 270 kG (600 lbs.)

C-Arm Movement & Dimension

  • Free space in arc:   32”
  • Depth of arc:   27”
  • Orbital rotation:  135 degrees
  • Horizontal Travel:  7.9”
  • Vertical Travel:  17.7”  .    Panning motion:  +/-  12.5 degrees
  • Pivot rotation:  +/-  180 degrees
  • Motion lock:  Friction locks for all motion
  • Steering handle:  Two front wheels
  • Brake:  Dual foot brake on side
  • Overscan 45 degrees

Full CDRH Compliance

KMC-950 C-Arm mobile system conforms to all applicable requirements of the Center for Devices and Radiological Health Department and Human Services, 21 CFR, Chapter 1, Subchapter J, at time of manufacture.

Power Requirement

Max Power:        3.3 KVA @ 110 VAC
12.0 KVA @ 220 VAC

Line Voltage:        110/220 VAC, 50/60 Hz

Line Current:        25-20 amp @ 110 VAC


SPINEL 3G SYSTEM SPECIFICATIONS

SPINAL 3G Specification Information

Digital Imaging Management System

H.F. Generator & Rotating Anode Tube with Digital Workstation

High Frequency Generator

  • 125kV/100 mA for Rad
  • 125kV/20 mA for Boost Fluoro

Microprocessor Control & APR Panel

LCD Touch Control Screen & Window

High Power Inverter:  12.5 kW

High Resolution II Tube:  9” II (Triple Mode)

X-Ray Tube:  Rotating Anode Tube

Focal Size:  0.3 – 0.6 mm micro filament

High resolution & contrast in image quality

Pulsed fluoro for dose reduction

Boost fluoro (20mA) for high contrast image

Auto Brightness Control (ABC) for fluoro image

Motorized & Rotating Collimator

CCD Camera     1K x 1K

19” LCD Flat Panel Monitor.  LIH and noise reduction

Digital Image Management System (CX-Viewer Software)

DICOM network (Send and Work List)

Power Requirement:  110/220 VCA, 50/60 Hz

45 degree over scan

32” Free space

CX-Viewer Digital Image Management Software & Processor

X-Ray Generator

Type:            High Frequency Inverter

Controller:        Microprocessor & PROM

OP Console:    LCD Touch Panel Screen and membrane switch

Mode:        Radiographic mode (Rad)
Fluoroscopic mode (FL)

Display Panel:    LCD Window & Screen

Power Rating:    12.5 kW Inverter

KV Range:        40-125kVp, 1.0 kV increment

Rad. mA Range:    20-100mA (programmable)

Rad. mAs Range:    0.2 to 500  mAs

Fluoro mA:        Normal FL: 0.3 – 5.0 mA
Multi-pulse:  0.3-5.0 mA
Snap FL:  8.0mA (8FPS)
Boost FL:   20 mA

Exp. Timer:    Rad. Mode:  3.0 ms to 8.0 sec
FL Mode:  0 to 5.0 minutes

Auto KV:        Automatic Brightness Control (ABC) on Fluoro mode of operation

X-Ray Tube

Type:            Rotating Anode (Rad-99, Varian)

Focal Size:        0.3 mm to 0.6 mm/micro focal

Anode Target:    10 degree Target Angle/TM

Heat Capacity:    300,000 HU

kV Capacity:    125 kVp

Filtration:        0.5 mm Al. @ 100 kV

Motorized Collimator

Type:            IRIS (circular) motor driven
Rotating:  360 degrees

Shutter:        One (1) pair lead blades

Diaphragms:    Two (2) sets of circular aperture

Filter:        2.5 mm AL. @ 100 kVp

Cassette Holder

Mount Type:    Mounting bracket on II Tube

Size:            24cm x 24cm  or 24cm x 30cm

Grid:            80 lines, 8:1 ratio,  28” – 32” focus

CCD Digital Camera

CCD Size:        1K x 1K

Video Signal:    1024 Lines/59.9 Hz (EIA)
Scan:  2:1 progressive

Aspect Ratio:    4:3  (H : V) ratio

Signal Output:    1:0 Vp-p  / 75 Ohm

Memory Capacity:        16 frame image memory (basic)
64 frame image memory (option)

Noise Reduction:        Up to 16 level selections

LIH:  Last Image Hold function

Image Rotation:        360 degrees continuously

 

 

Procedure Tables

CFPM400-Mid

 

 